Leoch LHR950W
Leoch LHR950W
Specification
Rated voltage
2 B
Rated power (W15)
1000 Vт/Эл at 15-мин discharge to U =1.67 W/El
Nominal capacity (C10)
300.0 Ah at discharge 10-час to U =1.80 W/El at 25 ˚С
Capacity на режимах
300.0 Ah at 10-час discharge to Uкон. =1.80 W/El at 25 ˚С, 282.0 Ah at 8-час discharge to Uкон. =1.80 W/El at 25 ˚С, 264.7 Ah at 5-час discharge to Uкон. =1.75 W/El at 25 ˚С, 230.1 Ah at 3-час discharge to Uкон. =1.75 W/El at 25 ˚С, 179.9 Ah at 1-час discharge to Uкон. =1.60 W/El at 25 ˚С
Weight
19.2 kg
Internal resistance
0.60 mOhm
Operating temperature
Discharge: -20 °C ~ 55 °C, Charge: -20 °C ~ 40 °C, Storage: -15 °C ~ 50 °C, Optimal operating temperature: 25 °С ± 3 °С
Charge voltage
Буферный режим 2.25 - 2.30 V, (темп. коэф. -3 мW/El/˚С), Vыравнивающий заряд 2.30 - 2.40 V, (темп. коэф. -4 мW/El/˚С)
Maximum charge current
75 А
Maximum discharge current
2400 А (5 sec.)
Self-discharge
≤ 3% в month, at 25 ˚С
dimensions
Length: 124 ± 2 мм, Width: 181 ± 2 мм, height: 350 ± 2 мм, height (макс.): 365 ± 2 мм
Housing material
Shockproof, негорючий ABS (acrylic butadiene styrene), соответствует UL94 HB или V-0 (опционально)
Output type
for bolt М8 (torque bolts 11.0-14.7 Нм)
Addiction Сном. (%) from t (˚С)
40 °C - 106%, 25 °C - 100%, 0 °C - 86%
Life time (при 25 ˚С)
16 years in buffer mode
*The battery must be charged before use. At higher ambient temperatures, storage time is reduced
Dimensions
Length
124
Width
181
Height
350
Height (full)
365
Direct current discharge: А (25°С)
Uk. / Tdischarge | 5 min | 10 min | 15 min | 20 min | 30 min | 45 min | 1 h | 1.5 h | 2 h | 3 h | 4 h | 5 h | 8 h | 10 h |
1.85 V/Эл | 569.0 | 518.0 | 427.0 | 341.0 | 276.7 | 183.7 | 158.4 | 118.5 | 93.3 | 72.8 | 57.8 | 50.6 | 34.1 | 29.3 |
1.80 V/Эл | 664.2 | 575.6 | 463.3 | 370.1 | 288.4 | 193.5 | 165.0 | 123.8 | 97.5 | 75.2 | 59.0 | 51.7 | 35.3 | 30.0 |
1.75 V/Эл | 735.9 | 633.1 | 495.1 | 395.0 | 304.0 | 200.3 | 166.7 | 127.5 | 99.6 | 76.7 | 60.1 | 52.9 | 35.7 | 30.4 |
1.70 V/Эл | 766.1 | 671.5 | 513.3 | 415.8 | 319.5 | 207.6 | 173.3 | 131.3 | 102.5 | 79.8 | 61.5 | 53.6 | 36.2 | 30.8 |
1.67 V/Эл | 783.8 | 681.1 | 540.5 | 432.4 | 329.7 | 212.7 | 176.6 | 135.0 | 104.6 | 81.3 | 63.4 | 54.7 | 36.6 | 31.1 |
1.60 V/Эл | 794.8 | 690.6 | 548.1 | 438.5 | 334.3 | 217.8 | 179.9 | 138.8 | 107.4 | 82.8 | 64.5 | 55.8 | 37.0 | 31.5 |
Constant power discharge: W/El (25°С)
Uk. / Tdischarge | 5 min | 10 min | 15 min | 20 min | 30 min | 45 min | 1 h | 1.5 h | 2 h | 3 h | 4 h | 5 h | 8 h | 10 h |
1.85 V/Эл | 1052.7 | 958.3 | 789.9 | 630.8 | 511.9 | 352.6 | 304.1 | 233.4 | 183.8 | 143.5 | 113.9 | 99.7 | 68.3 | 58.5 |
1.80 V/Эл | 1228.8 | 1064.8 | 857.1 | 684.6 | 533.5 | 371.5 | 316.8 | 243.8 | 192.1 | 148.0 | 116.1 | 101.9 | 70.5 | 60.0 |
1.75 V/Эл | 1361.4 | 1171.3 | 916.0 | 730.8 | 562.3 | 384.5 | 320.0 | 251.2 | 196.3 | 151.1 | 118.3 | 104.3 | 71.4 | 60.8 |
1.70 V/Эл | 1417.2 | 1242.3 | 949.6 | 769.2 | 591.2 | 398.5 | 332.6 | 258.6 | 201.9 | 157.1 | 121.2 | 105.6 | 72.3 | 61.5 |
1.67 V/Эл | 1450.0 | 1260.0 | 1000.0 | 800.0 | 609.9 | 408.3 | 339.0 | 266.0 | 206.0 | 160.1 | 124.9 | 107.8 | 73.2 | 62.3 |
1.60 V/Эл | 1470.3 | 1277.6 | 1014.0 | 811.2 | 618.4 | 418.1 | 345.3 | 273.3 | 211.6 | 163.2 | 127.1 | 110.0 | 74.0 | 63.0 |